8" SLAB NO TOPPINGSLAB D.L. 58 P.S.F.
ALLOWABLE UNIFORM SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  14 16 18 20 22 24 26 28 30 32 34 36 38 40
8-66 338 248 186 141 109 84 64 49 36 26        
8-86   338 257 199 156 124 98 78 62 49        
8-106     325 255 202 162 131 107 87 70 57 46    
8-68     351 276 220 177 144 117 96 78 63 51    
8-6826     401 317 254 205 168 138 114 94 77 64 52 43
FIRE RATING 1 HR. - 2 HRS.

8" SLAB + 2" TOPPINGSLAB D.L. 83 P.S.F.
ALLOWABLE UNIFORM SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  16 18 20 22 24 26 28 30 32 34 36 38    
8-66 308 229 171 131 99 74 53 32            
8-86   318 245 190 149 117 88 63 42          
8-106   403 313 247 197 156 120 92 68 48        
8-68     340 269 215 171 133 103 78 57 40      
8-6826     365 302 254 204 162 128 100 77 58      
FIRE RATING 1 HR. - 4 HRS.