32" x 12'-0" PRESTRESSED DOUBLE TEE NO TOPPING
ALLOWABLE SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84
128-D1   180 159 142 126 112 100 89 80 71 63 56 49 43 38 33 29            
148-D1     189 169 151 136 122 109 98 88 79 71 64 57 51 45 40 35 31 27      
168-D1           160 144 130 117 106 96 87 78 71 64 57 51 46 41 37 32 28  
188-D1                     110 100 91 83 75 68 62 56 50 45 41 36 32
208-D1                             86 78 71 65 59 54 49 44 39
228-D1                                     68 62 56 51 46

32" x 12'-0" PRESTRESSED DOUBLE TEE WITH 2" CONCRETE TOPPING
ALLOWABLE SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84
128-D1   199 174 152 133 117 102 89 78 67 58 50 42 35                  
148-D1     184 162 143 127 112 99 87 76 67 58 50 43 36 30              
168-D1           152 135 120 107 95 84 74 65 57 50 43 37 31 26        
188-D1                     100 89 79 70 62 55 48 42 36 30 25    
208-D1                             74 66 58 51 45 39 33 28  
228-D1                                     54 48 41 35 28


Use our navigation guide for quick access to all information on deAM-RON.com.

Contact us

deAM-RON is a Prestressed Concrete Institute approved manufacturer.
deAM-RON Building Systems, L.L.C
Manufacturer of Precast / Prestressed Concrete
P.O. Box 217
6137 U.S. Highway 60 East
Owensboro, Kentucky 42302
(270) 684-6226
Fax: (270) 684-8741
E-mail: sales@deAM-RON.com

Copyright © 2002 Contact the web site manager.
No text or illustrations may be used elsewhere without written permission.