16" x 8'-0" PRESTRESSED DOUBLE TEE NO TOPPING
ALLOWABLE SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
28-S 219 160 119 90 69 52 31                      
48-S       195 155 125 101 83 68 55 45 37 29          
68-S         184 151 126 105 88 74 63 53 44 37 31      
88-S             190 159 134 114 97 83 71 64 52 44 38 32

16" x 8'-0" PRESTRESSED DOUBLE TEE WITH 2" CONCRETE TOPPING
ALLOWABLE SUPERIMPOSED LOAD in LBS. PER SQ. FT.
SERIESSPAN in FEET
  14 16 18 20 22 24 26 28 30 32 34 36 38 40 42
28-S 243 173 126 91 66 47 32                
48-S         165 130 103 81 64 49 37        
68-S           199 162 132 108 88 72 58      
88-S             205 178 143 119 99 83 69 57 46